Smart Building Model

SmartBuilding : Model . Structure : Package . HVAC : Block (in SB-Systems / Data Network Block Definition Diagram / Security Block Definition Diagram)

Block Definition Diagram - HVAC link

Jump to:
HVAC HVAC Compressor Condenser Evaporator Expansion Valve Heating Coil Cooling Coil Air Damper Supply Fan Return Fan Air Handling Unit (AHU) Air Damper Air Terminal Unit (ATU) Air Terminal Unit (ATU) Fire Tube Boiler Water Tube Boiler Compressor Condenser Evaporator Cooling Tower Water-cooled System Air-cooled System Cooling Tower Expansion Valve Management level System-level Controller Field-level Controller Sensors HVAC Management level System-level Controller Field-level Controller Occupancy Sensor Sensors Sensors DDC Controller Air Damper Supply Fan Return Fan Heating Coil Variable Air Volume System (VAV) Field-level Controller Sensors Zigbee Variable Speed Relay Solenoid Electric Motor Actuator Air Handling Unit (AHU) Air Terminal Unit (ATU) Variable Speed Variable Speed Mixing Terminal Unit Air Terminal Unit (ATU) Heating Coil Cooling Coil Heating Coil Mixing Terminal Unit Air Damper Air Terminal Unit (ATU) FLOW :Association :Association :Generalization :Generalization :Association :Association :Association :Generalization :Generalization :Association :Association :Association :Association :Association :Association :Association :Generalization :Generalization :Association :Association :Association :Association :Generalization :Association :Generalization :Generalization :Generalization :Generalization :Generalization :Generalization :Association :Association :Association :Association :Association :Association :Association :Association :Association :Generalization :Generalization :Generalization :Generalization :Generalization :Generalization :Generalization :Generalization :Association :Association :Association :Association :Association :Association :Association :Generalization :Generalization :Association :Generalization :Generalization :Association :Association :Generalization :Generalization :Generalization :Association :Association :Association :Generalization :Generalization :Association :Association :Association :Association :Generalization :Generalization :Association :Association :Association :Association :Association :Association :Association :Association :Association :Association :Association :Association Humidity Control Devices:Block Condensate Tank:Block flow sensor:Block fan:Block Light Sensor:Block Airflow Distribution Control Devices:Block climate sensor:Block Centrifugal Pumps:Block Water Distribution Control Devices:Block Temperature Control Devices:Block Control Devices:Block Furnaces:Block Hydraulic System :Block Grill:Block Register:Block Single Zone:Block Building Space:Block Air Damper:Block Mixing Terminal Unit:Block Heating Coil:Block Cooling Coil:Block Heating Coil:Block Cold:Block Hot Duct:Block Return Air Duct:Block Duct:Block Variable Speed Fan:Block Fixed Speed Fan:Block Multi Zone:Block Forced Air System:Block control system and each system

air handling unit control application
heating control
cooling control
humidification control:Note outside-air temperature sensor:Block Actuator:Block Electric Motor:Block Solenoid:Block Relay:Block Variable Speed Drive:Block Wi-Fi Access Point:Block Telecommunication Outlet:Block Sensors:Block thermal sensor:Block Application-specific Controller:Block Variable Air Volume System (VAV):Block Return Fan:Block Filter:Block Supply Fan:Block Air Damper:Block Mechanical Controller:Block DDC Controller:Block air pressure sensors:Block static pressure sensors:Block Occupancy Sensor:Block Humidity Sensor:Block  CO2 sensor:Block Field-level Controller:Block System-level Controller:Block Management level:Block HVAC Control System:Block Expansion Valve:Block Cooling Tower:Block Pump:Block Air-cooled System:Block Water-cooled System:Block Evaporator:Block Condenser:Block Compressor:Block Water Tube Boiler:Block Fire Tube Boiler:Block Air Terminal Unit (ATU):Block Air Handling Unit (AHU):Block Chiller:Block Boiler:Block HVAC:Block

Model Elements
Name Description
  Humidity Control Devices : Block
  Condensate Tank : Block
  flow sensor : Block
  fan : Block
  Light Sensor : Block
  Airflow Distribution Control Devices : Block
  climate sensor : Block
  Centrifugal Pumps : Block
  Water Distribution Control Devices : Block
  Temperature Control Devices : Block
  Control Devices : Block
  Furnaces : Block
  Hydraulic System : Block
  Grill : Block
  Register : Block
  Single Zone : Block
  Building Space : Block
  Air Damper : Block
  Mixing Terminal Unit : Block
  Heating Coil : Block
  Cooling Coil : Block
  Cold : Block
  Hot Duct : Block
  Return Air Duct : Block
  Duct : Block
  Variable Speed Fan : Block
  Fixed Speed Fan : Block
  Multi Zone : Block
  Forced Air System : Block
  N/A : Note

control system and each system

 

air handling unit control application

heating control

cooling control

humidification control

  outside-air temperature sensor : Block
  Actuator : Block
  Electric Motor : Block

An electric motor is a device that converts electrical energy into rotating mechanical energy. It can be used open or close completely or partial dampers and valves.

  Solenoid : Block
  Relay : Block
  Variable Speed Drive : Block
  Wi-Fi Access Point : Block
  Telecommunication Outlet : Block
  Sensors : Block
  thermal sensor : Block
  Application-specific Controller : Block
  Variable Air Volume System (VAV) : Block
  Return Fan : Block
  Filter : Block
  Supply Fan : Block
  Mechanical Controller : Block
  DDC Controller : Block
  air pressure sensors : Block
  static pressure sensors : Block
  Occupancy Sensor : Block
  Humidity Sensor : Block
  CO2 sensor : Block
  Field-level Controller : Block
  System-level Controller : Block
  Management level : Block
  HVAC Control System : Block
  Expansion Valve : Block
  Cooling Tower : Block
  Pump : Block
  Air-cooled System : Block
  Water-cooled System : Block
  Evaporator : Block
  Condenser : Block
  Compressor : Block
  Water Tube Boiler : Block
  Fire Tube Boiler : Block
  Air Terminal Unit (ATU) : Block
  Air Handling Unit (AHU) : Block
  Chiller : Block
  Boiler : Block
  HVAC : Block
Smart Building Model